• Soğukpınar, Şile Otoyolu Yanyolu No:44
  • +90 (216) 499 2020
  • info@konformuhendislik.com
  • english turkish

Completed Projects

  • Nexus

    GULANPARK RESIDENCES AND OFFICES
    Erbil / Kurdistan Region / IRAQ

    Built Year: 2014
    Area: 80000 m2
    System: VRV
    Total Capacity: 6330 kW

    Equipments: 219 piece High Ambient Outdoor Units , 23 piecesmall VRV outdoor Units , 935 piece Wall Type Indoor Units , 297piece Cassette Type Indoor Units, 207 piece Ceiling Type DuctedIndoor Units, Integration to BMS System

  • Nexus

    DANIA CITY RESIDENCES
    Sulaimany / Kurdistan Region / IRAK

    Built Year: 2016-2017
    Area: 230000 m2
    System: VRV
    Total Capacity: 23050 kW

    Equipments: 696 piece High Ambient Outdoor Units , 3480 pieceSlim Ceiling Type Ducted Indoor Units ,1392 piece Wall Type Indoor Units

  • Nexus

    MARIANNA HOTEL2
    Erbil / Kurdistan Region / IRAQ

    Built Year: 2014
    Area: 11000 m2
    System: VRV
    Total Capacity: 2140 kW

    Equipments: 66 piece High Ambient Outdoor Units , 170 pieceCeiling Type Ducted Indoor Units ,13 piece Cassette Type Indoor Units,Integration to BMS System

  • Nexus

    ASIACELL OFFICE BUILDING
    Erbil / Kurdistan Region / IRAQ

    Built Year: 2013
    Area: 11000 m2
    System: VRV and ventilation systems
    Total Capacity: 1663 kW

    Equipments: 56 piece High Ambient Outdoor Units , 26 piece Wall Type Indoor Units , 112 piece Cassette Type Indoor Units, 37 piece Ceiling Type Ducted Indoor Units, Integration to BMS System

  • Nexus

    YENI HAYAT RESIDENCE AZURE MALL AND BUSINESS CENTER
    BAKU / AZERBAIJAN

    Built Year: 2012
    Area: 150000 m2
    System: All mechanic installation works
    Total Capacity: 12960 kW

    Equipments: Total 4.300 kW 3 piece Chiller , 405 piece Cassettetype FCU , 55 piece Ducted FCU,, 66 piece VRV Outdoor Units,177 piece Ceiling Type Ducted indoor Units, 66 piece Cassettetype indoor units , 853 piece Multi System Outdoor Units , 2.714 pieceEmura type indoor units.

  • Nexus

    NATIONAL HISTORY MUSEUM
    ASTANA / KAZAKHSTAN

    Built Year: 2013-2014
    Area: 85000 m2
    System: VRV
    Total Capacity: 7010 kW

    Equipments: 248 piece Water Cooled VRV Outdoor Units,10 piece Air Cooled VRV Outdoor Units, 281 piece CompactCassette type indoor units , 68 piece Cassette type indoor units,173 piece Ceiling Type Ducted indoor Units, Centralised Controlby I-touch Controller

  • Nexus

    KRASNAYA POLYANA APART HOTEL
    SOCHI/ RUSIA

    Built Year: 2013
    Area: 55000 m2
    System: VRV
    Total Capacity: 2248 kW

    Equipments: 58 piece VRV Outdoor Units , 833 piece Wall typeindoor units , 68 piece Cassette type indoor Units, integration toBMS system.

  • Nexus

    KOLUMAN SERVICE AND OFFICE BUILDING
    GAZIANTEP / TURKEY

    Built Year: 2016-2017
    Area: 30000 m2
    System: All Mechanical Works
    Total Capacity: 2250 kW

    Equipments: Total 2.250 kW 3 piece Chiller , 490 piece duct typetype FCU, 6 piece 600 kW Boiler , 4 piece AHU , Jet fan system forcarparks , 6 piece Fire pump , 5 group Hydrofor , Fans,, BMS systemfor all mechanical equipments.

  • Nexus

    TARSUS AMERICAN COLLEGE NEW CAMPUS
    MERSIN / TURKEY

    Built Year: 2013-2014
    Area: 14000 m2
    System: All mechanic installation works
    Total Capacity: 2065 kW

    Equipments: 26 piece heat pump VRV Outdoor Units ,156 piece Ceiling type ducted indoor units, 20 piece one wayblow cassette indoor units, 10 piece floor standing indoor units,2 piece wall type indoor units, 9 piece Roof-top AC units,3 piece AHUs , 2 piece Fire pumps , 3 sets Hydrofor, Fans ,BMS,integration to BMS for VRV units and Roof-top’s.

  • Nexus

    VOCATIONAL SCHOOL OF HEALTH SERVICES
    ADANA/ TURKEY

    Built Year: 2016
    Area: 7000 m2
    System: HVAC system
    Total Capacity: 1150 kW

    Equipments: 17 piece VRV Outdoor Units , 115 piece CassetteType Ducted Indoor Units, 9 piece DX coiled AHU , Centralized Controlby Intelligent Manager System , BMS system.

  • Nexus

    CITY’S NISANTASI SHOPPING MALL
    ISTANBUL / TURKEY

    Built Year: 2007
    Area: 60000 m2
    System: VRV
    Total Capacity: 4415 kW

    Equipments: 121 piece VRV Outdoor Units , 5 piece Heat-Recovery Outdoor Units , 3 piece Small VRV Outdoor Units,443 piece Ceiling Type Ducted Indoor Units, Centralized Controlby Intelligent Manager System , PPD Control (kwh consumption),7 pair Split AC for Electrical rooms.

  • Nexus

    AKASYA ACIBADEM RESIDENCES
    ISTANBUL / TURKEY

    Built Year: 2013
    Area: 80000 m2
    System: VRV
    Total Capacity: 5723 kW

    Equipments: 169 piece VRV Outdoor Units , 1503 piece Walltype indoor units , 296 piece Ceiling Type Ducted Indoor Units,489 piece 2 way Cassette type indoor units , Centralized Controlby Intelligent Manager System , PPD Control (kwh consumption).

  • Nexus

    FOUR WINDS GOZTEPE RESIDENCES
    ISTANBUL / TURKEY

    Built Year: 2013-2014
    Area: 115000 m2
    System: VRV
    Total Capacity: 7087 kW

    Equipments: 178 piece Heat recovery VRV Outdoor Units ,9 piece Heat pump VRV Outdoor Units , 2034 piece Ceiling typeslim ducted indoor units , 424 piece Ceiling Type Ducted Indoor Units,4 piece Cassette type indoor units , 12 piece concealed floorstanding type indoor units , Centralized Control by IntelligentManager System , PPD Control (kwh consumption).

  • Nexus

    ORYAPARK RESIDENCE
    ISTANBUL / TURKEY

    Built Year: 2015-2017 (Under Construction)
    Area: 85000 m2
    System: VRV
    Total Capacity: 3600 kW

    Equipments: 144 piece Water Cooled VRV Outdoor Units ,526 piece Ceiling type Ducted indoor units, 400 piece Wall typeindoor units, Centralized Control by Intelligent Touch Manager System ,PPD Control (kwh consumption),

  • Nexus

    AVRUPA RESIDENCES-TEM
    ISTANBUL / TURKEY

    Built Year: 2011
    Area: 25000 m2
    System: VRV
    Total Capacity: 1966 kW

    Equipments: 61 piece VRV Outdoor Units , 227 piece Ceilingtype Ducted indoor units, 242 piece Ceiling type Slim Ductedindoor units , 3 piece Wall type indoor units,Centralized Controlby Intelligent Manager System , PPD Control (kwh consumption),

  • Nexus

    KOLUMAN SAMANDIRA OFFICE
    ISTANBUL / TURKEY

    Built Year: 2007
    Area: 10000 m2
    System: VRV and ventilation works
    Total Capacity: 777 kW

    Equipments: 18 piece Heat-Recovery VRV Outdoor Units ,133 piece Ceiling type Ducted indoor units, 17 piece VAMheat reclaim ventilation , Centralized Control by IntelligentManager System

  • Nexus

    KOLUMAN MERCEDES GOZTEPE SHOWROOM
    ISTANBUL / TURKEY

    Built Year: 2003
    Area: 6000 m2
    System: VRV and ventilation works
    Total Capacity: 196 kW

    Equipments: 8 piece Heat-Recovery VRV Outdoor Units ,28 piece Ceiling type Ducted indoor units, 13 piece Cassettetype indoor units , Centralized Control by I-touch Controller

  • Nexus

    KOLUMAN MERCEDES SHOWROOM-OFFICE
    GAZIANTEP / TURKEY

    Built Year: 2006
    Area: 20000 m2
    System: VRV and ventilation works
    Total Capacity: 529 kW

    Equipments: 12 piece VRV Outdoor Units , 2 piece Roof-Top,1 piece multi system outdoor unit , 60 piece Cassette type indoorunits , 4 piece Ceiling type Ducted indoor units, 12 piece Walltype indoor units , 5 piece floor standing type indoor units13 piece VAM heat reclaim ventilation , Centralized Controlby Intelligent Manager System

  • Nexus

    ELEGANCE HOTEL-MARMARIS
    MUGLA/ TURKEY

    Built Year: 2006
    Area: 10000 m2
    System: VRV
    Total Capacity: 1100 kW

    Equipments: 30 piece Heat pump VRV Outdoor Units ,1 piece Heat recovery VRV Outdoor Unit, 4 piece multi systemoutdoor units , 194 piece Ceiling type slim ducted indoor units ,56 piece Ceiling type ducted indoor units, 13 piece Walltype indoor units , 5 piece split type AC , Centralized Controlby Intelligent Manager System

  • Nexus

    CETINKAYA ALTIPARMAK AND HEYKEL SHOP. CENT.
    BURSA / TURKEY

    Built Year: 2011-2012
    Area: 8250 m2
    System: VRV
    Total Capacity: 694 kW

    Equipments: 21 piece Heat pump VRV Outdoor Units ,83 piece Cassette type indoor units , 17 piece Wall typeindoor units , Centralized Remote Controller

  • Nexus

    KIPTAS DRAGOS KONAKLARI
    ISTANBUL / TURKEY

    Built Year: 2010
    Area: 30000 m2
    System: VRV
    Total Capacity: 1792 kW

    Equipments: 128 piece Heat pump Small VRV Outdoor Units , 700 piece Ceiling type slim ducted indoor units

  • Nexus

    1.LEVENT PLAZA OFFICE BUILDING
    ISTANBUL / TURKEY

    Built Year: 1999
    Area: 80000 m2
    System: VRV
    Total Capacity: 3971 kW

    Equipments: 63 piece Heat recovery VRV Outdoor Units ,85 piece Heat pump VRV Outdoor Units , 362 piece Concealedfloor standing indoor units , 79 piece Ceiling type high ESPducted indoor Units (big), 56 piece Cassette type indoor units ,standing type indoor units , Centralized Remote Controller.

  • Nexus

    KIPTAS HEAD OFFICE BUILDING
    ISTANBUL / TURKEY

    Built Year: 2011
    Area: 8000 m2
    System: VRV
    Total Capacity: 515 kW

    Equipments: 15 piece Heat recovery VRV Outdoor Units ,100 piece Ceiling type ducted indoor units, 13 piece heat reclaimventilation unit with DX coil (VKM) , Centralized Control byIntelligent Manager System.